Five-year outcomes of implantation of Absorb biodegradable stents using the bifurcation stenting technique: a case report
https://doi.org/10.15829/1728-8800-2021-2864
Abstract
The presented case report describes a five-year outcomes of bifurcation stenting of the left anterior descending artery and large diagonal branch with Absorb bioabsorbable vascular stent (BVS) according to selective coronary angiography and optical coherence tomography. The example demonstrates not only the successful implantation of biodegradable stents into the bifurcation area, but also the complete restoration of the arterial wall with the formation of neocarina. Optical coherence tomography made it possible to study in detail all stages of vascular wall alterations from the inside. This case report prompts a fresh look at the biodegradable BVS Absorb stents and does not rule out the potential of returning these stents to clinical practice in the future. Currently, the production and use of Absorb BVSs has been suspended, but they have filled a certain niche in the endovascular treatment of patients with coronary artery disease.
About the Authors
D. G. IoselianiRussian Federation
D. A. Asadov
Russian Federation
V. V. Fomenko
Russian Federation
A. V. Azarov
Russian Federation
S. P. Semitko
Russian Federation
References
1. Kereiakes DJ, Ellis SG, Metzger C et al. 3-Year clinical outcomes with Everolimus-Eluting Bioresorbable coronary Scaffolds: The ABSORB III Trial. Journal of the American College of Cardiology 2017;70 (23): 2875-2877. doi: 10.1016/j.jacc.2017.10.010.
2. Kimura T, Kozuma K, Tanabe K et al. A randomized trial evaluating everolimus-eluting Absorb bioresorbable scaffolds vs. everolimus-eluting metallic stents in patients with coronary artery disease: ABSORB Japan. European Heart Journal. 2015; 36(47): 3332–42. doi: 10.1093/eurheartj/ehv435.
3. Lassen JF, Holm NR, Stankovic G et al. Percutaneous coronary intervention for coronary bifurcation disease: consensus from the first 10 years of the European Bifurcation Club meetings. Eurointervention 2014; 10: 545-560. doi: 10.4244/EIJV10I5A97.
4. Vahl TP, Gaisor P, Gongora CA et al. Four-year polymer biocompatibility and vascular healing profile of a novel ultrahigh molecular weight amorphous PLLA bioresorbable vascular scaffold: an OCT study in healthy porcine coronary arteries. Eurointervention 2016; 12:1510-18. doi: 10.4244/EIJ-D-16-00308.
Supplementary files
Review
For citations:
Ioseliani D.G., Asadov D.A., Fomenko V.V., Azarov A.V., Semitko S.P. Five-year outcomes of implantation of Absorb biodegradable stents using the bifurcation stenting technique: a case report. Cardiovascular Therapy and Prevention. 2021;20(4):2864. (In Russ.) https://doi.org/10.15829/1728-8800-2021-2864